Bard Power Port: Understanding the Complications and Injuries

Injuries

Bard Power Ports, integral components in modern medical procedures, play a crucial role in facilitating intravenous treatments for patients. These medical devices are implanted beneath the skin to provide reliable access points for intravenous medications and treatments.

Despite their widespread use, the landscape surrounding it has become increasingly complex, marked by reports of complications and injuries.

This article aims to comprehensively explore the world of Bard Power Ports. It sheds light on the intricacies of design, functionality, and common applications in medical settings.

Complications and Injuries Associated with the Bard Power Port

Some of the primary complications and injuries linked to the device include:

Catheter Fracture

When a catheter breaks inside the body, it can lead to severe complications. These complications may include embolisms, organ damage, hemorrhage, and, in some tragic cases, even death.

A notable instance highlighting the gravity of catheter fractures involves an Illinois woman, Crystal Sussen. Sussen filed a product liability lawsuit after encountering problems with multiple Bard PowerPort devices implanted for cancer treatments.

According to AboutLawsuits.com, Sussen’s ordeal began when the first Bard implantable port catheter fractured merely six months after implantation. The shattered catheter sent fragments into her bloodstream and heart, causing severe injuries.

The subsequent replacement, implanted in November 2011, was found to be nonfunctional by October 2015. This led to the surgical removal of the device, emphasizing the persistent and potentially life-threatening complications associated with catheter fractures.

Catheter Migration

One of the primary concerns associated with catheter migration is the potential for restricted blood flow. If the catheter migrates into a position that obstructs a blood vessel, it can significantly reduce blood supply to the affected area. This can potentially lead to tissue damage or organ dysfunction.

Another potential complication of catheter migration is the disruption of medication delivery. Catheters are often used to administer medications directly into the bloodstream or to drain fluids from the body. If the catheter migrates out of position, it may no longer be able to effectively perform its intended function.

In some cases, catheter migration may not cause any noticeable symptoms. However, patients should be aware of the potential risks and should promptly report any changes in their condition.

Infections

According to ConsumerSafety, the risk of infection is inherent in all catheter implants. However, those filing lawsuits allege that Bard PowerPorts, in particular, are faulty and associated with heightened infection risks.

Patients claim that Bard did not adequately disclose the increased risk of infections. Moreover, some infections developed later than anticipated, suggesting design flaws in the device that allowed bacterial growth months after implantation.

Symptoms of infection related to Power Ports include fever, chills, inflammation, swelling, and changes in urine color or odor. The severity of these infections cannot be understated, with bloodstream infections posing a risk of progressing to sepsis.

Additionally, infections from catheters can complicate overall patient care, necessitating a focus on catheter-related infections. This may, in turn, delay critical treatments for primary diagnoses such as cancer.

Blood Clots

Blood clots associated with the Bard Power Port are most likely to occur in the catheter itself or the veins surrounding the port. These clots can pose significant health risks, including:

  • Pulmonary embolisms: If a clot breaks off and travels to the lungs, it can block a blood vessel, causing a pulmonary embolism. This can lead to shortness of breath, chest pain, and even death.
  • Heart attack: If a clot blocks a coronary artery, it can deprive the heart of oxygen, leading to a heart attack. Symptoms of a heart attack include chest pain, shortness of breath, and nausea.
  • Stroke: If a clot blocks a blood vessel in the brain, it can cause a stroke. Symptoms of a stroke include numbness on one side of the body, difficulty speaking, and vision problems.

Factors Contributing to Complications

The alleged complications stem from multiple contributing factors, including design flaws, manufacturing defects, and potential surgical errors during implantation. Notably, concerns have been raised regarding design flaws, particularly the use of material prone to fissuring and cracking.

Manufacturing defects represent another critical factor contributing to device-related issues. The intricate nature of medical device production leaves room for errors that may compromise the overall safety of Bard Power Ports. The susceptibility of these devices to defects raises concerns about the quality control processes in place during manufacturing.

Surgical errors during implantation constitute an additional factor contributing to complications. In some cases, errors made during the surgical procedure may exacerbate the risks associated with the device.

Notably, the ongoing Bard Power Port lawsuit is consolidated within the Bard Implanted Port Catheter Products Liability Litigation (MDL 3081). This consolidation exemplifies the collective legal efforts made by individuals who have encountered problems with the device.

TorHoerman Law reports that as of September 2023, 50 cases are included in this multidistrict litigation, slated for a hearing on November 16th, 2023. These legal proceedings underscore the necessity for a comprehensive investigation and accountability.

FDA Regulation in Connection to Bard Power Port

The U.S. Food and Drug Administration (FDA) plays a critical role in regulating medical devices. It reviews and approves medical devices based on their safety and efficacy.

According to Drugwatch, in March 2020, the FDA issued a recall for three Bard PowerPort models. This was due to a potential risk of incorrectly containing a tunneler with an incorrect barb tip. The recall highlights the importance of FDA oversight in protecting patient safety.

Conclusion

It is crucial for patients to actively seek information regarding the risks associated with Bard Power Ports, empowering them to make informed decisions. The ongoing lawsuit highlights the collaborative endeavor to address this concern and hold manufacturers accountable for the safety of the device.

Encouraging open communication between patients and healthcare providers also plays a pivotal role in nurturing a culture of transparency. It ensures that the pursuit of medical interventions remains grounded in the principles of the safety and welfare of individuals.